Accessories:
                                            
                                            
                                        
									    Installation Kit
Maintenance Kit
                                    
                                
    						
								
                                    
                                        
                                            
                                                Accuracy:
                                            
                                            
                                        
									    ± 5 % or ±0.03 mg/L (ppm) as CL2, whichever is greater
                                    
                                
    						
								
                                    
                                        
                                            
                                                Air purge:
                                            
                                            
                                        
									    0.1 cfm (0.17 m³/h) instrument quality air at max. 20 psi (ca.1.4 bar) with ¼" OD tube, quick disconnect fitting
                                    
                                
    						
								
                                    
                                        
                                            
                                                Alarm:
                                            
                                            
                                        
									    Two alarms selectable for sample concentration alarm, analyser system warning, or analyser system shut-down alarm. Each is equipped with an SPDT relay with contacts rated for 5A resistive load at 230 V AC.
                                    
                                
    						
								
                                    
                                        
                                            
                                                Certifications:
                                            
                                            
                                        
									    Europe, CE Approved with:
EN 61326-1
CISPR 11
EN 61010-1
IEC 60529
                                    
                                
    						
								
                                    
                                        
                                            
                                                Communication capabilities:
                                            
                                            
                                        
									    4-20 mA output
                                    
                                
    						
								
                                    
                                        
                                            
                                                Cycle Time:
                                            
                                            
                                        
									    2.5 min
                                    
                                
    						
								
                                    
                                        
                                            
                                                Description:
                                            
                                            
                                        
									    CL17 Chlorine Analyzer with Reagents for Total Chlorine
                                    
                                
    						
								
                                    
                                        
                                            
                                                Detection limit:
                                            
                                            
                                        
									    0.03 mg/L (ppm)
                                    
                                
    						
								
                                    
                                        
                                            
                                                Display:
                                            
                                            
                                        
									    LCD, 3.5 inch digit measurement readout and six-character alphanumeric scrolling text line
                                    
                                
    						
								
                                    
                                        
                                            
                                                Drain:
                                            
                                            
                                        
									    1/2-inch ID flexible hose, hose barb
                                    
                                
    						
								
                                    
                                        
                                            
                                                Enclosure Construction:
                                            
                                            
                                        
									    ABS plastic, two clear polycarbonate windows, IP62-rated with the gasketed door latched.
                                    
                                
    						
								
                                    
                                        
                                            
                                                Flow rate:
                                            
                                            
                                        
									    200 - 500 mL per minute minimum required
                                    
                                
    						
								
                                    
                                        
                                            
                                                Includes:
                                            
                                            
                                        
									    CL17 Chlorine Analyser with 1 Month Supply of Total Chlorine Reagents, Maintenance kit, Installation Kit, and Manual. (The power cord is ordered separately.)
                                    
                                
    						
								
                                    
                                        
                                            
                                                Inlet:
                                            
                                            
                                        
									    ¼" OD polyethylene tube, quick-disconnect fitting
                                    
                                
    						
								
                                    
                                        
                                            
                                                Inlet pressure:
                                            
                                            
                                        
									    1 to 5 psi (0.07 - 0.34 bar), 1.5 psi (0.103 bar) is optimum
                                    
                                
    						
								
                                    
                                        
                                            
                                                Interferences:
                                            
                                            
                                        
									    Other oxidizing agents such as bromide, chlorine dioxide, permanganate and ozone will cause a positive interference. Hexavalent chromium will cause a positive interference: 
1 mg/L Cr6+ = approximately 0.02 mg/L as Cl2. 
Hardness must not exceed 1,000 mg/L CaCO3.
                                    
                                
    						
								
                                    
                                        
                                            
                                                Light source:
                                            
                                            
                                        
									    Class 1 LED (light emitting diode) with a peak wavelength of 520 nm; 50,000 hours estimated minimum life
                                    
                                
    						
								
                                    
                                        
                                            
                                                Measuring range:
                                            
                                            
                                        
									    0 - 5 mg/L Cl₂
                                    
                                
    						
								
                                    
                                        
                                            
                                                Mounting:
                                            
                                            
                                        
									    Wall mount
                                    
                                
    						
								
                                    
                                        
                                            
                                                Operating humidity:
                                            
                                            
                                        
									    Up to 90 % at 40 °C (104 °F) maximum
                                    
                                
    						
								
                                    
                                        
                                            
                                                Operating temperature range:
                                            
                                            
                                        
									    5 - 40 °C
                                    
                                
    						
								
                                    
                                        
                                            
                                                Parameter:
                                            
                                            
                                        
									    Chlorine, Free & Total
                                    
                                
    						
								
                                    
                                        
                                            
                                                Power requirements (Amps):
                                            
                                            
                                        
									    2.5 A
                                    
                                
    						
								
                                    
                                        
                                            
                                                Power requirements (Hz):
                                            
                                            
                                        
									    50/60 Hz
                                    
                                
    						
								
                                    
                                        
                                            
                                                Power requirements (Voltage):
                                            
                                            
                                        
									    100 - 115/230 V AC
                                    
                                
    						
								
                                    
                                        
                                            
                                                Pressure range:
                                            
                                            
                                        
									    Inlet Pressure to Sample Conditioning:  1.5 - 75 psi (0.1 - 5.2 bar)
                                    
                                
    						
								
                                    
                                        
                                            
                                                Pressure Regulator Included?:
                                            
                                            
                                        
									    No
                                    
                                
    						
								
                                    
                                        
                                            
                                                Recorder outputs:
                                            
                                            
                                        
									    One 0/4-20 mA with an output span programmable over any portion of the 0 to 5 mg/L range. Recommended load impedance 3.6 to 500 ohms, 130 V isolation from earth ground.
                                    
                                
    						
								
                                    
                                        
                                            
                                                Repeatability:
                                            
                                            
                                        
									    0.01 ppm or 3.0 % , whichever is greater
                                    
                                
    						
								
                                    
                                        
                                            
                                                Sample temperature:
                                            
                                            
                                        
									    5 - 40 °C (41 - 104 °F)
                                    
                                
    						
								
                                    
                                        
                                            
                                                Warranty:
                                            
                                            
                                        
									    24 months
                                    
                                
    						
								
                                    
                                        
                                            
                                                Weight:
                                            
                                            
                                        
									    11.3 kg
                                    
                                
    						
								
                                    
                                        
                                            
                                                What's included?:
                                            
                                            
                                        
									    CL17 Chlorine Analyser with 1 Month Supply of Total Chlorine Reagents, Maintenance kit, Installation Kit, and Manual. (The power cord is ordered separately.)