Hach Online Process ORP Sensor - Clean Water Digital ORP Sensor

Hach Online Process ORP Sensor - Clean Water Digital ORP Sensor
Product #: DRD1R5.99
Unit Price Contact Us
Available

Longer service life

This field-proven technique uses three electrodes instead of the two normally used in conventional ORP sensors. Process and reference electrodes measure the ORP differentially with respect to a third ground electrode. The end result is unsurpassed measurement accuracy, reduced reference junction potential, and elimination of sensor ground loops. These sensors provide greater reliability, resulting in less downtime and maintenance.

24-month phased warranty*

The double junction salt bridge creates a barrier to contamination which minimizes the dilution of the internal standard cell solution. The result is lower maintenance needs and a longer time period between calibrations.

Plug and play with SC controllers

The unique, replaceable salt bridge holds an extraordinary volume of buffer to extend the working life of the sensor by protecting the reference electrode from harsh process conditions. The salt bridge simply threads onto the end of the sensor if replacement is needed.

Reliability with Built-in Encapsulated Preamp

Encapsulated construction protects the sensor’s built-in preamp from moisture and humidity, ensuring reliable sensor operation. The preamp in the pHD analog sensor produces a strong signal, enabling the sensor to be located up to 1000 m (3280 ft.) from the analyzer.

Innovative Technology

The former GLI, now a Hach Company brand, invented the Differential Electrode Technique for pH measurement in 1970. The pHD sensor series takes this field-proven technology to a new level.

Specifications

Accuracy: ± 0.5 °C
  ± 5 mV
Body Material: PPS
Cable connection: Digital
Cable length: 10 m
  10 m PUR (polyurethane) 4-conductor with one shield, rated to 105 °C
Calibration method: one point manual
Communication: MODBUS
Compliance: Hazardous location, Maritime, CE
Diameter: 35.4 mm
Drift: 2 mV per 24 hours, non-cumulative
Electrode type: General Purpose
Flow: Max. 3 m/s
Housing material: PPS
Length: 271.3 mm
Material: Titanium
Material (electrode): Platinum
Measuring range: -1500 to +1500 mV ORP
Mounting: Convertible
Operating temperature range: –5 to 70 °C (23 to 158 °F) pHD and ORP

Before initial pH calibration, calibrate the temperature measurement when the sensor is in water or buffer which is at approximately the same temperature as the pH buffers.
Pressure range: Max. 10.7 bar Sensor only (pressure range of mounting hardware to be checked separately)
Repeatability: ± 2 mV
Sensor Thread: 1" NPT at both ends
Sensor type : Digital
Temperature accuracy: ± 0.5 °C (± 0.9 °F)
Temperature sensor: NTC 300 Ω thermistor for temperature readout, not for temperature compensation
Warranty: 24 months
Weight: 0.316 kg
Wetted materials: PPS, PVDF junction, glass and platinum, titanium ground electrode, FKM/FPM o-ring seals