Accessories included:
USB charger, power cable, and clips
Auto-buffer recognition:
Yes
Backlight:
Yes
Cable length:
1 m
Calibration intervals/alerts/reminder:
Off, selectable from 2 hours to 7 days
Certifications:
CE, FCC, ISED, RCM, KC, ETL Verified: US DOE/ NRCan Energy Efficiency, RoHS
Conductivity calibration:
Demal (1D/ 0.1D/ 0.01D);
Molar (0.1M/ 0.01M/0.001M);
NaCl (0.05%; 25µS/cm; 1000µS/cm; 18mS/cm);
Standard sea water;
User defined
Conductivity measurement: Temperature correction:
None; Linear; NaCl Non-Linear Natural Water.
Conductivity measurement range:
Yes
Custom calibration standards:
Yes
Data logger:
USB connection to PC or USB storage device (limited to the storage device capacity).
Data memory:
5000 data points
Data Storage:
Automatic in Press to Read Mode and Interval Mode. Manual in Continuous Read Mode.
Dimensions (H x W x D):
63 mm x 97 mm x 220 mm
Display:
Up to 3 parameters at a time, dependent on HQ model
Display type:
536x336 Mono-TFT
Electrode type:
Intellical Standard Laboratory or Rugged Field
Enclosure waterproof rating:
IP67 (with battery compartment installed)
Environmental conditions: relative humidity:
90% (non-condensing)
Environmental conditions: temperature:
0 - 60 °C
GLP features:
Date; Time; Sample ID; Operator ID, Calibration
Inputs:
1
Instrument:
Portable
ISE direct measurement:
No
ISE electrode calibration:
No
Kit?:
Yes
Languages user interface:
English, Chinese - Simplified, Spanish, French, German, Italian, Japanese, Turkish, Dutch, Portuguese (PT & BR), Korean, Danish, Swedish, Polish, Norwegian, Hungarian, Greek, Finnish, Czech, Romanian, Croatian, Bulgarian, Slovak, Lithuanian, Estonian, Slovenian, Russian
Lock function:
Continuous / Auto-stabilisation ("press to read") / At Interval
Measurement method:
Probe specific programmed method settings
Model:
HQ1140 EC/TDS/1 Channel
mV measurement at stable reading:
No
mV measurement range:
No
mV resolution:
0.1 mV
Operating error messages:
Clear text error messages displayed
Operating Interface:
Soft Touch Keypad
Parameter:
Conductivity/Total Dissolved Solids (TDS)
Power supply:
Rechargeable lithium-ion battery 18650 (internal)
Class II, USB power adapter: 100 - 240 VAC, 50/60 Hz input; 5 VDC at 2 A USB power adapter output (external)
Probes included?:
CDC40101
Protection class:
IEC Class III (SELV (Separated/Safety Extra-Low Voltage) powered); external
Resolution:
0.01 mg/L - 0.1 g/L upon measuring range
Salinity measurement range:
0 - 42 (ppt) (‰)
Salinity resolution:
0.01 (ppt) (‰)
Sensor A:
CDC40105
Sensor B:
None
Sensor C:
None
Storage conditions:
-20 - 60 °C, max. 90% relative humidity (non-condensing)
TDS measurement range:
0.00 mg/L - 50.0 g/L NaCl
Temperature compensation:
Automatic Temperature compensation for pH
Temperature measurement range:
°C or °F
Temperature resolution:
0.1 °C
Type of measurement:
Field Measurements
Warranty:
24 months
Weight:
519 g (Meter only)
What's included?:
LEV015.98.1140A HQ1140 Portable EC/TDS Meter, 1 channel
CDC40101 Intellical conductivity cell, 1 m cable
LEZ015.99.A001A HQ standard electrode field case
LEZ015.99A003A HQ hand strap & kickstand
LEZ015.99.A004A HQ protective glove
EZZ073 Disposable paper tissues, white, pk/200
2771420 Singlet single-use conductivity standard solution, 1413 µS/cm, KCl, 20 mL
User manuals