HQ30D Digital portable multi meter kit, one channel, w/ PHC201 standard gel pH & CDC401 conductivity electrodes, 1 m cable

OBSOLETE ITEM

HQ30D Digital portable multi meter kit, one channel, w/ PHC201 standard gel pH & CDC401 conductivity electrodes, 1 m cable
Product #: HQ30D.99.121201

OBSOLETE ITEM

Outstanding reliability and simple handling

Versatile electrodes for all applications, e.g. wastewater, drinking water, process water

Reliable results from inaccessible measurement locations and over long distances - even for pH

Error-free O2 results - without calibration or replacing the electrolyte

Full GLP data management

What's included

Meter package includes HQ30D Portable Meter; 4 AA batteries, PHC201 Laboratory General Purposes Gel Filled pH Electrode, 1 m Cable; CDC401 Laboratory 4-Poles Graphite Conductivity Cell, 1 m Cable; quick-start guide and user manuals; Standard Field case; Protective Glove for Portable HQd Meter; 120 mL Sample Container (x5); Singlet pH 4 & 7 Buffer pouches 10 of each; Sodium Chloride Standard Solution, 491 mg/L NaCl (1000 µS/cm), 100 mL

Specifications

AC Power Adapter and USB/DC Adapter: Optional
Auto-buffer recognition: IUPAC standards
(DIN 19266) or Technical buffer (DIN 19267) or 4-7-10 series or customer defined
Barometric pressure measurement: Automatic compensation of DO when using an LDO or LBOD probe
Calibration intervals/alerts/reminder: Off, selectable from 2 hours to 7 days
Casing IP rating: IP67
Compliance certifications: CE marking
Conductivity accuracy: ± 0.5 from 1 µS/cm to 200 mS/cm
Conductivity calibration: Demal (1D/ 0.1D/ 0.01D);
Molar (0.1M/ 0.01M/0.001M);
NaCl (0.05%; 25µS/cm; 1000µS/cm; 18mS/cm);
Standard sea water;
Customer defined
Conductivity measurement: Temperature correction: None; Linear; NaCl Non-Linear Natural Water.
Conductivity measurement at stable reading: 5 different stability modes
Conductivity measurement range: 0.01 µS/cm to 200 mS/cm
Conductivity resolution: 5 digits with 2 digits after decimal point
Contents: No
Custom calibration standards: Custom defined standards possible
Data logger: Download via USB connection to PC or flash memory device. Automatically transfer entire data log or as readings are taken. Power supply adapter required.
Data memory: 500 records/FIFO
Data Storage: Automatic, GLP ISO compliant reading data stored with batteriescalibration details.
Display: Detailed mode/Large mode
Display type: 240 x 160 pixel LCD with batteriesbacklight illumination
DO measurement range: 0.1 to 20.0 mg/L (ppm) 1 to 200% saturation
DO resolution: 0.1
DO sensor calibration: * 100% (water-saturated air (100%) calibration
* 100% with 0 (water-saturated air (100%) calibration with 0 point
* mg/L (calibration with a specified dissolved oxygen concentration (mg/L) solution)
* mg/L with 0 (calibration with a specified dissolved oxygen concentration (mg/L) solution with 0 point)
* Factory (calibration with the default LDO calibration)
Electrode type: Standard
Environmental conditions: relative humidity: 90 % relative humidity (non-condensing)
Environmental conditions: temperature: 0 - 60 °C (32 - 140 °F)
GLP features: Date; Time; Sample ID; Operator ID
Includes: Meter package includes HQ30D Portable Meter; 4 AA batteries, PHC201 Laboratory General Purposes Gel Filled pH Electrode, 1 m Cable; CDC401 Laboratory 4-Poles Graphite Conductivity Cell, 1 m Cable; quick-start guide and user manuals; Standard Field case; Protective Glove for Portable HQd Meter; 120 mL Sample Container (x5); Singlet™ pH 4 & 7 Buffer pouches 10 of each; Sodium Chloride Standard Solution, 491 mg/L NaCl (1000 µS/cm), 100 mL
Inputs: 1
Instrument: Portable
ISE direct measurement: Yes
ISE electrode calibration: 2 to 5 Points
Kit?: Yes
Languages user interface: Selectable: English, French, German, Italian, Spanish, Danish, Dutch, Polish, Portuguese, Turkish, Swedish, Czech, Russian
Lock function: Continuous / Auto-stabilization ("press to read") / At Interval
Manual languages: English, French, Italian, German, Spanish, Bulgarian, Croatian, Czech, Dutch, Danish, Estonian, Finnish, Greek, Hungarian, Lithuanian, Polish, Portuguese, Romanian, Russian, Slovak, Slovenian, Swedish, Turkish
Measurement method: Probe specific programmed method settings
Model: HQ30D – Multi/1 Channel
mV measurement at stable reading: 5 different stability modes
mV measurement range: -1500 - 1500 mV
mV resolution: 0.1 mV
Needed Cable Length: 1
Operating error messages: full text messages
Operating Interface: keypad
ORP electrode calibration: Predefined ORP standards (including Zobell's solution)
Parameter: pH, mV, ISE, DO, Conductivity, TDS, Salinity, Resistivity, ORP, Temp
Parameters: pH
Conductivity
NA
PC data transfer software : HQD Data Transfer Utility
pH Buffer Sets: IUPAC standards
(DIN 19266) or Technical buffer (DIN 19267) or 4-7-10 series or customer defined
pH Electrode calibration: 1 - 3 Calibration points
Calibration summary data logged and displayed
pH Measurement Range: 0 - 14 pH
pH Resolution: Selectable:
0.001/0.01/0.1 pH
Printer: as optional accessory
Probes included?: PHC20101, CDC40101
Resolution: 0.01 mg/L up - 0.1 g/L upon measuring range
Result ID: time stamp, user ID, sample-ID, etc.
Salinity measurement range: 0 - 42 (ppt) (‰)
Salinity resolution: 0.01 (ppt) (‰)
Sensor A: PHC20101 (1 m)
Sensor B: CDC40101 (1 m)
Sensor C: NA
Sensors: Sensor A: PHC20101
Sensor B: CDC40101
Sensor C:
Simultaneous measurements: Yes, 2 channels
TDS measurement range: 0.00 mg/L - 50.0 g/L as NaCl
Temperature accuracy: ± 0.3 °C
Temperature compensation: Automatic Temperature compensation for pH
Temperature measurement range: °C or °F
Temperature resolution: 0.1
Type of measurement: Field Measurements
Warranty: 36 months
Weight: 409 g (0.75 lb) without batteries; 430 g (0.95 lb) with batteries
What's included?: Meter package includes HQ30D Portable Meter; 4 AA batteries, PHC201 Laboratory General Purposes Gel Filled pH Electrode, 1 m Cable; CDC401 Laboratory 4-Poles Graphite Conductivity Cell, 1 m Cable; quick-start guide and user manuals; Standard Field case; Protective Glove for Portable HQd Meter; 120 mL Sample Container (x5); Singlet pH 4 & 7 Buffer pouches 10 of each; Sodium Chloride Standard Solution, 491 mg/L NaCl (1000 µS/cm), 100 mL