Orbisphere K1100 LDO Sensor Kit, 0-40 ppm, 410 controller, ¼" flow chamber, panel mount

Orbisphere K1100 LDO Sensor Kit, 0-40 ppm, 410 controller, ¼
Product #: K110H-KTO-P-IMP
Unit Price Contact Us
Ships within 2 weeks

One calibration per year

One zero point calibration per year is all that is needed with the K1100 sensor. Designed for minimal drift, luminescent technology makes the K1100 sensor the most stable sensor with the longest calibration interval in the industry.

No membranes = two minutes of maintenance

With no membranes to replace and no electrolyte solution to replenish, the K1100 requires only two minutes of maintenance per year. Corrosive or hazardous chemicals are not required, making the annual task faster, easier and safer without reducing measurement precision.

Low cost retrofit

The complete system consists of a controller, a flow chamber, and the K1100 Luminescent Dissolved Oxygen Sensor. The sensor is compatible with Hach Orbisphere 28 mm flow chambers, eliminating the need for engineering changes. Installation is fast and easy and does not require special preparation.

A new level of confidence

The K1100 optical sensor is the first to use luminescent measurement technology to measure both ppb and ppm oxygen levels in power plants. Since 1978, Hach Orbisphere sensors have set the industry standard for oxygen measurement by delivering confidence to every water chemistry manager. The K1100 maintains this tradition and offers significant operating and cost benefits.

What's included

Includes 410 panel mount controller, K1100 LDO sensor (high level), 3 m sensor cable, stainless steel flow-chamber with ¼" fittings

Specifications

Accuracy: ± 0.02 ppm or 3 % whichever is greater
Ambient temperature: -5 - 50 °C
Analogue outputs: 3 Smart 0/4 to 20 mA (500 Ohms) programmable as linear or tri-linear, configurable to send diagnostics or alarm informations.
Application: Power
Calibration: Two points at cap replacement (zero and air), one during use (air)
Certifications: 2004/108/EC - EN 61326-1
Communication capabilities: 3 x 0/4-20 mA; RS485; Ethernet
Controller: Panel
Controller Options: 410 Mono-Channel Controller
Detection limit: 0.015 ppm
Display resolution: 0.1 ppb
Flow rate: 50 - 300 mL/min
Measuring range: 0 - 40 ppm dissolved O₂ (DO)
Mounting: 1/4" flow chamber
Parameter: Oxygen
Power requirements (Voltage): 100 - 230 V AC
Relays: Measurement board: 3 measurement alarm relays (1A-30 VAC or 0.5A-50 VDC), configurable to send diagnostics information.
Main board: 1 system alarm relay (1A-30 VAC or 0.5A-50 VDC).
Repeatability: ± 0.015 ppm or 2 % whichever is greater
Reproducibility: ± 0.02 ppm or 3 % whichever is greater
Response time: (90%) <10 s (gas phase); <50 s (liquid phase)
Sample pressure: 1 - 20 bar absolute (14.5 - 290 psi)
Sample temperature: -5 - 50°C
Sensors: K1100 LDO
Storage conditions: -5 °C - 100 °C
Temperature range: Accurate from -5 - 50 °C
Resistant - temperature from -5 - 100 °C
Warranty: 24 months
Weight: 0.6 kg
What's included?: Includes 410 panel mount controller, K1100 LDO sensor (high level), 3 m sensor cable, stainless steel flow-chamber with ¼" fittings