UVAS plus sc UV probe for organic load (immersion/bypass), 5 mm path length

UVAS plus sc UV probe for organic load (immersion/bypass), 5 mm path length
Product #: LXV418.99.50001
Unit Price Contact Us
Ships within 1 week

Continuous, automatic early warning systems

Use the Hach® UVAS plus sc UV Absorbance/Transmittance sensor to continuously protect plant treatment processes from high influent organic loads.

Control activated sludge processes

Activated sludge processes require precise balancing of organic load, aeration, and nutrients. Continuous trending of the organics using the UVAS plus sc sensor can help operators learn how to balance other factors resulting in cost and time savings.

Suitable for quaternary treatment

The combination of two Hach UVAS plus sc sensors allows continuous monitoring of micropollutants reduction in advanced treatment stages.

Self-cleaning wiper system

The detector windows are automatically cleaned by a built-in wiper that eliminates surface films or particles that can reduce accuracy.

Monitor effciency of UV disinfection process

Hach’s UVAS plus sc is designed to provide continuous UV light transmittance (UVT) measurement of pre-disinfected source water. Operational costs related to sampling for UVT may be reduced with continuous on-line measurement.

What's included

UVAS plus sc probe, user manual

Specifications

Application: Outlet; Drinking water; Surface water
Cable length: 10 m fixed cable at sensor
Compensation: 550 nm
Configurations: Sensor only
Connections: Bypass: 4 mm ID / 6 mm OD hose
Control: Control Function: PID, time control, 2-point controller (with SC controller)
Controller: Sensor only
Controller compatibility: SC4500, SC1000, SC200
Diameter: 70 mm
Dimensions: 70 x 333 mm (2.75 x 13.11 in.) approx.
Flow rate: Bypass: 0.5 L/h minimum
Length: 333 mm
Maintenance requirements: 1 h/month in standard applications
Material: Sensor enclosure: stainless steel 316, 1.4571, single sealed body
Wiper axle: stainless steel 1.4104
Cable gland: stainless steel 1.4305
Cable gland seal: PVDF
Profile carrier: stainless steel 1.4310
Wiper arm: stainless steel 1.4581
Wiper profile: Silicone
Measuring window: Suprasil (quartz glass)
Measurement method: UV absorption measurement (unique 2-beam technique)
SAC 254 in accordance with DIN 38404 C3
Measuring interval: ≥ 1 min
Measuring range: 0.1 - 600 m­¹
Operating temperature range: 2 - 40 °C
Parameter: SAC
Path Length: 5 mm
pH Range: 4.5 - 9 pH
Pressure range: ≤ 0.5 bar
Service interval: 6 months
User maintenance: 1 h/month, typical
Warranty: 24 months
Weight: 3.6 kg approx.
What's included?: UVAS plus sc probe, user manual